Dear Lars!
Thank you for your help! Problem solved.
https://bugs.wireshark.org/bugzilla/show_bug.cgi?id=4467
Br, Adam
Hi, That's probably because Wireshark can't determine the sampling rate. Speex uses a dynamic payload type. So Wireshark needs to have signaling info (SIP/SDP, H.323, ...) in your trace to figure out the sampling rate. Do you have this?
To Dev people: Actually we *don't need* the sampling rate in order to calcualte packet delta! But in practice it seems we don't calculate it if we don't have a sampling rate. => could be fixed.
Regards, Lars
Hi all! I have a problem with rtp stream analyzer, i' m useing speex codec 8000hz sample rate and vbr. I see "0" in delta column every rows instead of the real delta values. Everything fine with PCMA, g711, g729, gsm... but speex. I tried the 1.2.2 and 1.2.6 and 1.3.2 dev versions... Same result, no delta values Can anybody help me with this problem? Br, Adam
Hotmail: Hatékony, ingyenes e-mail szolgáltatás a Microsoft által biztosított védelemmel. Töltse le most!
|