Hi all,
There is an inconsistency in WTP display of packet sequence numbers:
sometimes BASE_DEC is used, sometimes BASE_HEX.
As has been discussed in earlier mails, this packet sequence numbers are
unsigned integers and not opaque data, so they should be represented as
decimal values. The following patch fixes this:
--- packet-wtp-1.40.c 2002-12-02 12:25:30.000000000 +0100
+++ packet-wtp.c 2002-12-02 12:28:31.000000000 +0100
@@ -798,14 +798,14 @@
{ &hf_wtp_header_sequence_number,
{ "Packet Sequence Number",
"wtp.header.sequence",
- FT_UINT8, BASE_HEX, NULL, 0x00,
+ FT_UINT8, BASE_DEC, NULL, 0x00,
"Packet Sequence Number", HFILL
}
},
{ &hf_wtp_header_missing_packets,
{ "Missing Packets",
"wtp.header.missing_packets",
- FT_UINT8, BASE_HEX, NULL, 0x00,
+ FT_UINT8, BASE_DEC, NULL, 0x00,
"Missing Packets", HFILL
}
},
Please check in.
Regards,
Olivier Biot Siemens ATEA IC D MS C
O-------------------------------o-------------------------------O
| Phone : +32 (14) 25 39 84 | Address: Atealaan 34 |
| Fax : +32 (14) 22 29 94 | 2200 Herentals |
| Cellular: +32 (474) 96 32 09 | Belgium |
O-------------------------------o-------------------------------O
~ "I love deadlines. I especially love the swooshing sound ~
~ they make as they go flying by." - Dilbert ~
_______________________________________________
Ethereal-dev mailing list
Ethereal-dev@xxxxxxxxxxxx
http://www.ethereal.com/mailman/listinfo/ethereal-dev