Display Filter Reference: ZigBee ZCL Energy Management
Protocol field name: zbee_zcl_se.em
Versions: 2.6.0 to 3.4.5
Back to Display Filter Reference
Field name | Description | Type | Versions |
---|---|---|---|
zbee_zcl_se.energy_management.action_required | Action(s) Required | Unsigned integer, 1 byte | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.action_required.disable_duty_cycling | Disable Duty Cycling | Boolean | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.action_required.enable_duty_cycling | Enable Duty Cycling | Boolean | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.action_required.opt_into_event | Opt Into Event | Boolean | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.action_required.opt_out_of_event | Opt Out of Event | Boolean | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.action_required.reserved | Reserved | Unsigned integer, 1 byte | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.attr.attr_reporting_status | Attribute Reporting Status | Unsigned integer, 1 byte | 2.6.0 to 3.4.5 |
zbee_zcl_se.energy_management.attr_id | Attribute | Unsigned integer, 2 bytes | 2.6.0 to 3.4.5 |
zbee_zcl_se.energy_management.cmd.srv_rx.id | Command | Unsigned integer, 1 byte | 2.6.0 to 3.4.5 |
zbee_zcl_se.energy_management.cmd.srv_tx.id | Command | Unsigned integer, 1 byte | 2.6.0 to 3.4.5 |
zbee_zcl_se.energy_management.device_class | Device Class | Unsigned integer, 2 bytes | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.device_class.electric_vehicle | Electric Vehicle | Boolean | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.device_class.exterior_lighting | Exterior Lighting | Boolean | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.device_class.generation_systems | Generation Systems | Boolean | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.device_class.hvac_compressor_or_furnace | HVAC Compressor or Furnace | Boolean | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.device_class.interior_lighting | Interior Lighting | Boolean | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.device_class.irrigation_pump | Irrigation Pump | Boolean | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.device_class.managed_c_i_loads | Managed Commercial & Industrial (C&I) loads | Boolean | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.device_class.pool_pump_spa_jacuzzi | Pool Pump/Spa/Jacuzzi | Boolean | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.device_class.reserved | Reserved | Unsigned integer, 2 bytes | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.device_class.simple_misc_loads | Simple misc. (Residential On/Off) loads | Boolean | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.device_class.smart_appliances | Smart Appliances | Boolean | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.device_class.strip_heaters_baseboard_heaters | Strip Heaters/Baseboard Heaters | Boolean | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.device_class.water_heater | Water Heater | Boolean | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.issuer_id | Issuer Event ID | Unsigned integer, 4 bytes | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.report_event.average_load_adjustment_percentage_applied | Average Load Adjustment Percentage Applied | Signed integer, 1 byte | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.report_event.cooling_temperature_set_point_applied | Cooling Temperature Set Point Applied | Signed integer, 2 bytes | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.report_event.criticality_level_applied | Criticality Level Applied | Unsigned integer, 1 byte | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.report_event.duty_cycle_applied | Duty Cycle Applied | Unsigned integer, 1 byte | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.report_event.event_control | Event Control | Unsigned integer, 1 byte | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.report_event.event_status | Event Status | Unsigned integer, 1 byte | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.report_event.event_status_time | Event Status Time | Date and time | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.report_event.heating_temperature_set_point_applied | Heating Temperature Set Point Applied | Signed integer, 2 bytes | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.report_event.issuer_id | Issuer Event ID | Unsigned integer, 4 bytes | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.report_event.randomize_duration_time | Randomize Duration time | Boolean | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.report_event.randomize_start_time | Randomize Start time | Boolean | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.reserved | Reserved | Unsigned integer, 1 byte | 3.2.0 to 3.4.5 |
zbee_zcl_se.energy_management.utility_enrollment_group | Utility Enrollment Group | Unsigned integer, 1 byte | 3.2.0 to 3.4.5 |