Display Filter Reference: ZigBee ZCL DLRC

Protocol field name: zbee_zcl_se.drlc

Versions: 2.6.0 to 3.4.5

Back to Display Filter Reference

Field name Description Type Versions
zbee_zcl_se.drlc.attr.attr_reporting_status Attribute Reporting Status Unsigned integer, 1 byte 2.6.0 to 3.4.5
zbee_zcl_se.drlc.attr_client_id Attribute Unsigned integer, 2 bytes 3.0.0 to 3.4.5
zbee_zcl_se.drlc.attr_id Attribute Unsigned integer, 2 bytes 2.6.0 to 2.6.20
zbee_zcl_se.drlc.average_load_adjustment_percentage Average Load Adjustment Percentage Signed integer, 1 byte 3.2.0 to 3.4.5
zbee_zcl_se.drlc.cancel_control Cancel Control Unsigned integer, 1 byte 3.2.0 to 3.4.5
zbee_zcl_se.drlc.cancel_control.event_in_process Event in process Boolean 3.2.0 to 3.4.5
zbee_zcl_se.drlc.cancel_control.reserved Reserved Unsigned integer, 1 byte 3.2.0 to 3.4.5
zbee_zcl_se.drlc.cmd.srv_rx.id Command Unsigned integer, 1 byte 2.6.0 to 3.4.5
zbee_zcl_se.drlc.cmd.srv_tx.id Command Unsigned integer, 1 byte 2.6.0 to 3.4.5
zbee_zcl_se.drlc.cooling_temperature_offset Cooling Temperature Offset Unsigned integer, 1 byte 3.2.0 to 3.4.5
zbee_zcl_se.drlc.cooling_temperature_set_point Cooling Temperature Set Point Signed integer, 2 bytes 3.2.0 to 3.4.5
zbee_zcl_se.drlc.criticality_level Criticality Level Unsigned integer, 1 byte 3.2.0 to 3.4.5
zbee_zcl_se.drlc.device_class Device Class Unsigned integer, 2 bytes 3.2.0 to 3.4.5
zbee_zcl_se.drlc.device_class.electric_vehicle Electric Vehicle Boolean 3.2.0 to 3.4.5
zbee_zcl_se.drlc.device_class.exterior_lighting Exterior Lighting Boolean 3.2.0 to 3.4.5
zbee_zcl_se.drlc.device_class.generation_systems Generation Systems Boolean 3.2.0 to 3.4.5
zbee_zcl_se.drlc.device_class.hvac_compressor_or_furnace HVAC Compressor or Furnace Boolean 3.2.0 to 3.4.5
zbee_zcl_se.drlc.device_class.interior_lighting Interior Lighting Boolean 3.2.0 to 3.4.5
zbee_zcl_se.drlc.device_class.irrigation_pump Irrigation Pump Boolean 3.2.0 to 3.4.5
zbee_zcl_se.drlc.device_class.managed_c_i_loads Managed Commercial & Industrial (C&I) loads Boolean 3.2.0 to 3.4.5
zbee_zcl_se.drlc.device_class.pool_pump_spa_jacuzzi Pool Pump/Spa/Jacuzzi Boolean 3.2.0 to 3.4.5
zbee_zcl_se.drlc.device_class.reserved Reserved Unsigned integer, 2 bytes 3.2.0 to 3.4.5
zbee_zcl_se.drlc.device_class.simple_misc_loads Simple misc. (Residential On/Off) loads Boolean 3.2.0 to 3.4.5
zbee_zcl_se.drlc.device_class.smart_appliances Smart Appliances Boolean 3.2.0 to 3.4.5
zbee_zcl_se.drlc.device_class.strip_heaters_baseboard_heaters Strip Heaters/Baseboard Heaters Boolean 3.2.0 to 3.4.5
zbee_zcl_se.drlc.device_class.water_heater Water Heater Boolean 3.2.0 to 3.4.5
zbee_zcl_se.drlc.duration_in_minutes Duration In Minutes Unsigned integer, 2 bytes 3.2.0 to 3.4.5
zbee_zcl_se.drlc.duty_cycle Duty Cycle Unsigned integer, 1 byte 3.2.0 to 3.4.5
zbee_zcl_se.drlc.effective_time Reserved Unsigned integer, 4 bytes 3.2.0 to 3.4.5
zbee_zcl_se.drlc.event_control Event Control Unsigned integer, 1 byte 3.2.0 to 3.4.5
zbee_zcl_se.drlc.get_scheduled_events.issuer_event_id Issuer Event ID Unsigned integer, 1 byte 3.2.0 to 3.4.5
zbee_zcl_se.drlc.get_scheduled_events.numbers_of_events Number of Events Unsigned integer, 1 byte 3.2.0 to 3.4.5
zbee_zcl_se.drlc.get_scheduled_events.start_time Start Time Date and time 3.2.0 to 3.4.5
zbee_zcl_se.drlc.heating_temperature_offset Heating Temperature Offset Unsigned integer, 1 byte 3.2.0 to 3.4.5
zbee_zcl_se.drlc.heating_temperature_set_point Heating Temperature Set Point Signed integer, 2 bytes 3.2.0 to 3.4.5
zbee_zcl_se.drlc.issuer_id Issuer Event ID Unsigned integer, 4 bytes 3.2.0 to 3.4.5
zbee_zcl_se.drlc.randomize_duration_time Randomize Duration time Boolean 3.2.0 to 3.4.5
zbee_zcl_se.drlc.randomize_start_time Randomize Start time Boolean 3.2.0 to 3.4.5
zbee_zcl_se.drlc.report_event.average_load_adjustment_percentage_applied Average Load Adjustment Percentage Applied Signed integer, 1 byte 3.2.0 to 3.4.5
zbee_zcl_se.drlc.report_event.cooling_temperature_set_point_applied Cooling Temperature Set Point Applied Signed integer, 2 bytes 3.2.0 to 3.4.5
zbee_zcl_se.drlc.report_event.criticality_level_applied Criticality Level Applied Unsigned integer, 1 byte 3.2.0 to 3.4.5
zbee_zcl_se.drlc.report_event.duty_cycle_applied Duty Cycle Applied Unsigned integer, 1 byte 3.2.0 to 3.4.5
zbee_zcl_se.drlc.report_event.event_control Event Control Unsigned integer, 1 byte 3.2.0 to 3.4.5
zbee_zcl_se.drlc.report_event.event_status Event Status Unsigned integer, 1 byte 3.2.0 to 3.4.5
zbee_zcl_se.drlc.report_event.event_status_time Event Status Time Date and time 3.2.0 to 3.4.5
zbee_zcl_se.drlc.report_event.heating_temperature_set_point_applied Heating Temperature Set Point Applied Signed integer, 2 bytes 3.2.0 to 3.4.5
zbee_zcl_se.drlc.report_event.issuer_id Issuer Event ID Unsigned integer, 4 bytes 3.2.0 to 3.4.5
zbee_zcl_se.drlc.report_event.signature Signature Sequence of bytes 3.2.0 to 3.4.5
zbee_zcl_se.drlc.report_event.signature_type Signature Type Unsigned integer, 1 byte 3.2.0 to 3.4.5
zbee_zcl_se.drlc.reserved Reserved Unsigned integer, 1 byte 3.2.0 to 3.4.5
zbee_zcl_se.drlc.start_time Start Time Unsigned integer, 4 bytes 3.2.0 to 3.4.5
zbee_zcl_se.drlc.utility_enrollment_group Utility Enrollment Group Unsigned integer, 1 byte 3.2.0 to 3.4.5
Go Beyond with Riverbed Technology

Riverbed is Wireshark's primary sponsor and provides our funding. They also make great products that fully integrate with Wireshark.

I have a lot of traffic...

ANSWER: SteelCentral™ AppResponse 11
  • • Full stack analysis – from packets to pages
  • • Rich performance metrics & pre-defined insights for fast problem identification/resolution
  • • Modular, flexible solution for deeply-analyzing network & application performance
Learn More