Display Filter Reference: ZigBee Application Support Layer
Protocol field name: zbee.aps
Versions: 1.2.0 to 1.8.15
Back to Display Filter Reference
Field name | Description | Type | Versions |
---|---|---|---|
zbee.aps.ack_format | Acknowledgement Format | Boolean | 1.6.0 to 1.8.15 |
zbee.aps.ack_mode | Acknowledgement Mode | Boolean | 1.2.0 to 1.4.15 |
zbee.aps.ack_req | Acknowledgement Request | Boolean | 1.2.0 to 1.8.15 |
zbee.aps.block | Block Number | Unsigned integer, 1 byte | 1.2.0 to 1.8.15 |
zbee.aps.cluster | Cluster | Unsigned integer, 2 bytes | 1.2.0 to 1.8.15 |
zbee.aps.cmd.addr | Device Address | Unsigned integer, 2 bytes | 1.2.0 to 1.8.15 |
zbee.aps.cmd.challenge | Challenge | Sequence of bytes | 1.2.0 to 1.8.15 |
zbee.aps.cmd.device | Device Address | EUI64 address | 1.2.0 to 1.8.15 |
zbee.aps.cmd.dst | Extended Destination | EUI64 address | 1.2.0 to 1.8.15 |
zbee.aps.cmd.ea.data | Data | Sequence of bytes | 1.2.0 to 1.8.15 |
zbee.aps.cmd.ea.key_type | Key Type | Unsigned integer, 1 byte | 1.2.0 to 1.8.15 |
zbee.aps.cmd.id | Command Identifier | Unsigned integer, 1 byte | 1.2.0 to 1.8.15 |
zbee.aps.cmd.init_flag | Initiator | Boolean | 1.2.0 to 1.8.15 |
zbee.aps.cmd.initiator | Initiator Address | EUI64 address | 1.2.0 to 1.8.15 |
zbee.aps.cmd.key | Key | Sequence of bytes | 1.2.0 to 1.8.15 |
zbee.aps.cmd.key_type | Key Type | Unsigned integer, 1 byte | 1.2.0 to 1.8.15 |
zbee.aps.cmd.mac | Message Authentication Code | Sequence of bytes | 1.2.0 to 1.8.15 |
zbee.aps.cmd.partner | Partner Address | EUI64 address | 1.2.0 to 1.8.15 |
zbee.aps.cmd.responder | Responder Address | EUI64 address | 1.2.0 to 1.8.15 |
zbee.aps.cmd.seqno | Sequence Number | Unsigned integer, 1 byte | 1.2.0 to 1.8.15 |
zbee.aps.cmd.src | Extended Source | EUI64 address | 1.2.0 to 1.8.15 |
zbee.aps.cmd.status | Device Status | Unsigned integer, 1 byte | 1.2.0 to 1.8.15 |
zbee.aps.counter | Counter | Unsigned integer, 1 byte | 1.2.0 to 1.8.15 |
zbee.aps.delivery | Delivery Mode | Unsigned integer, 1 byte | 1.2.0 to 1.8.15 |
zbee.aps.dst | Destination Endpoint | Unsigned integer, 1 byte | 1.2.0 to 1.8.15 |
zbee.aps.ext_header | Extended Header | Boolean | 1.2.0 to 1.8.15 |
zbee.aps.fragment | Message fragment | Frame number | 1.2.0 to 1.8.15 |
zbee.aps.fragment.count | Message fragment count | Unsigned integer, 4 bytes | 1.6.0 to 1.8.15 |
zbee.aps.fragment.error | Message defragmentation error | Frame number | 1.2.0 to 1.8.15 |
zbee.aps.fragment.multiple_tails | Message has multiple tail fragments | Boolean | 1.2.0 to 1.8.15 |
zbee.aps.fragment.overlap | Message fragment overlap | Boolean | 1.2.0 to 1.8.15 |
zbee.aps.fragment.overlap.conflicts | Message fragment overlapping with conflicting data | Boolean | 1.2.0 to 1.8.15 |
zbee.aps.fragment.too_long_fragment | Message fragment too long | Boolean | 1.2.0 to 1.8.15 |
zbee.aps.fragmentation | Fragmentation | Unsigned integer, 1 byte | 1.2.0 to 1.8.15 |
zbee.aps.fragments | Message fragments | Label | 1.2.0 to 1.8.15 |
zbee.aps.group | Group | Unsigned integer, 2 bytes | 1.2.0 to 1.8.15 |
zbee.aps.indirect_mode | Indirect Address Mode | Boolean | 1.2.0 to 1.8.15 |
zbee.aps.profile | Profile | Unsigned integer, 2 bytes | 1.2.0 to 1.8.15 |
zbee.aps.reassembled.in | Reassembled in | Frame number | 1.2.0 to 1.8.15 |
zbee.aps.reassembled.length | Reassembled ZigBee APS length | Unsigned integer, 4 bytes | 1.4.0 to 1.8.15 |
zbee.aps.security | Security | Boolean | 1.2.0 to 1.8.15 |
zbee.aps.src | Source Endpoint | Unsigned integer, 1 byte | 1.2.0 to 1.8.15 |
zbee.aps.type | Frame Type | Unsigned integer, 1 byte | 1.2.0 to 1.8.15 |