Display Filter Reference: V.150.1 State Signaling Event
Protocol field name: v150fw
Versions: 1.10.0 to 3.4.5
Back to Display Filter Reference
Field name | Description | Type | Versions |
---|---|---|---|
v150fw.cleardown_vendor_info | Vendor-specific info | Unsigned integer, 1 byte | 1.10.0 to 3.4.5 |
v150fw.cleardown_vendor_tag | Vendor tag | Unsigned integer, 1 byte | 1.10.0 to 3.4.5 |
v150fw.eflen | Extension field length | Unsigned integer, 2 bytes | 1.10.0 to 3.4.5 |
v150fw.event | Event ID | Unsigned integer, 1 byte | 1.10.0 to 3.4.5 |
v150fw.extb | Payload extension | Boolean | 1.10.0 to 3.4.5 |
v150fw.frb | Force response | Boolean | 1.10.0 to 3.4.5 |
v150fw.remainder | Remaining bytes | Sequence of bytes | 1.10.0 to 3.4.5 |
v150fw.reserved | Reserved | Unsigned integer, 2 bytes | 1.10.0 to 3.4.5 |
v150fw.ric | Reason ID | Unsigned integer, 1 byte | 1.10.0 to 3.4.5 |
v150fw.ricinfo | Info | Unsigned integer, 2 bytes | 1.10.0 to 3.4.5 |
v150fw.ricinfo.cleardown | Cleardown type | Unsigned integer, 2 bytes | 1.10.0 to 3.4.5 |
v150fw.ricinfo.cleardown_reserved | Reserved for use by the ITU-T | Unsigned integer, 2 bytes | 1.10.0 to 3.4.5 |
v150fw.ricinfo.timeout | Timeout type | Unsigned integer, 2 bytes | 1.10.0 to 3.4.5 |
v150fw.ricinfo.timeout_vendor | Vendor-specific timeout info | Unsigned integer, 2 bytes | 1.10.0 to 3.4.5 |
v150fw.rinfo.mod_avail | Modulation availability | Unsigned integer, 2 bytes | 1.10.0 to 3.4.5 |
v150fw.rinfo.mod_avail.half_duplex | V.23 half-duplex | Boolean | 1.10.0 to 3.4.5 |
v150fw.rinfo.mod_avail.pcm_mode | PCM mode | Boolean | 1.10.0 to 3.4.5 |
v150fw.rinfo.mod_avail.v17 | V.17 | Boolean | 1.10.0 to 3.4.5 |
v150fw.rinfo.mod_avail.v21 | V.21 | Boolean | 1.10.0 to 3.4.5 |
v150fw.rinfo.mod_avail.v22_v22bis | V.22/V.22bis | Boolean | 1.10.0 to 3.4.5 |
v150fw.rinfo.mod_avail.v23_duplex | V.23 duplex | Boolean | 1.10.0 to 3.4.5 |
v150fw.rinfo.mod_avail.v26bis | V.26bis | Boolean | 1.10.0 to 3.4.5 |
v150fw.rinfo.mod_avail.v26ter | V.26ter | Boolean | 1.10.0 to 3.4.5 |
v150fw.rinfo.mod_avail.v27ter | V.27ter | Boolean | 1.10.0 to 3.4.5 |
v150fw.rinfo.mod_avail.v29_half_duplex | V.29 half-duplex | Boolean | 1.10.0 to 3.4.5 |
v150fw.rinfo.mod_avail.v32_v32bis | V.32/V.32bis | Boolean | 1.10.0 to 3.4.5 |
v150fw.rinfo.mod_avail.v34_duplex | V.34 duplex | Boolean | 1.10.0 to 3.4.5 |
v150fw.rinfo.mod_avail.v34_half_duplex | V.34 half-duplex | Boolean | 1.10.0 to 3.4.5 |
v150fw.rinfo.mod_avail.v90_or_v92_analog | V.90 or V.92 analog | Boolean | 1.10.0 to 3.4.5 |
v150fw.rinfo.mod_avail.v90_or_v92_digital | V.90 or V.92 digital | Boolean | 1.10.0 to 3.4.5 |
v150fw.rinfo.mod_avail.v91 | V.91 | Boolean | 1.10.0 to 3.4.5 |
Go Beyond with Riverbed Technology
I have a lot of traffic...
ANSWER: SteelCentral™ AppResponse 11
- • Full stack analysis – from packets to pages
- • Rich performance metrics & pre-defined insights for fast problem identification/resolution
- • Modular, flexible solution for deeply-analyzing network & application performance