Display Filter Reference: SERCOS III V1.1
Protocol field name: siii
Versions: 1.8.0 to 3.4.5
Back to Display Filter Reference
Field name | Description | Type | Versions |
---|---|---|---|
siii.at.cp0.num_devices | Number of Devices | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
siii.at.cp0.sercos_address | Sercos Address | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
siii.at.devstatus | Word | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.at.devstatus.commwarning | Communication Warning | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.at.devstatus.errorconnection | Topology Status | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.at.devstatus.inactportstatus | Port 1 Status | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.at.devstatus.paralevelactive | Parameterization level active | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.at.devstatus.proccmdchange | Procedure Command Change | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.at.devstatus.slavevalid | Slave data valid | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.at.devstatus.topologychanged | Topology Change | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.at.devstatus.topstatus | Topology Status | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.at.hp.error | Error | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.at.hp.hp0_finished | HP/SVC | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.at.hp.info | HP info | Sequence of bytes | 1.8.0 to 3.4.5 |
siii.at.hp.parameter | Parameter Received | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.at.hp.sercosaddress | Sercos address | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.at.sercosaddress | Sercos Address | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
siii.at.supfunctions | Support of requested functions | Boolean | 2.0.0 to 3.4.5 |
siii.at.svch.ahs | Handshake | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.at.svch.info | Svc Info | Sequence of bytes | 1.8.0 to 3.4.5 |
siii.channel | Channel | Unsigned integer, 1 byte | 1.8.0 to 3.4.5 |
siii.cp_unknown | CP is unknown | Label | 2.0.0 to 3.4.5 |
siii.cyclecntvalid | Cycle Count Valid | Boolean | 1.8.0 to 3.4.5 |
siii.device_controls | Device Controls | Label | 2.0.0 to 3.4.5 |
siii.device_status | Device Status | Label | 2.0.0 to 3.4.5 |
siii.idn_code | IDN code | Unsigned integer, 4 bytes | 2.0.0 to 3.4.5 |
siii.mdt.devcontrol | Word | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.mdt.devcontrol.identrequest | Identification | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.mdt.devcontrol.topcontrol | Topology Control | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.mdt.devcontrol.topologychange | Changing Topology | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.mdt.hp.ctrl | HP control | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.mdt.hp.info | HP info | Sequence of bytes | 1.8.0 to 3.4.5 |
siii.mdt.hp.parameter | Parameter | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.mdt.hp.sercosaddress | Sercos address | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.mdt.hp.stat | HP status | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.mdt.hp.switch | Switch to SVC | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.mdt.svch.busy | Busy | Boolean | 1.8.0 to 3.4.5 |
siii.mdt.svch.ctrl | SvcCtrl | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.mdt.svch.data.proccmd.interrupt | Procedure Command Execution | Unsigned integer, 2 bytes | 1.8.0 to 1.8.15 |
siii.mdt.svch.data.proccmd.set | Procedure Command | Unsigned integer, 2 bytes | 1.8.0 to 1.8.15 |
siii.mdt.svch.data.telassign.mdt_at | Telegram Type | Unsigned integer, 2 bytes | 1.8.0 to 1.8.15 |
siii.mdt.svch.data.telassign.offset | Telegram Offset | Unsigned integer, 2 bytes | 1.8.0 to 1.8.15 |
siii.mdt.svch.data.telassign.telno | Telegram Number | Unsigned integer, 2 bytes | 1.8.0 to 1.8.15 |
siii.mdt.svch.dbe | Data block element | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.mdt.svch.eot | End of element transmission | Boolean | 1.8.0 to 3.4.5 |
siii.mdt.svch.error | SVC Error | Boolean | 1.8.0 to 3.4.5 |
siii.mdt.svch.idn | IDN | Unsigned integer, 4 bytes | 1.8.0 to 3.4.5 |
siii.mdt.svch.info | Svc Info | Sequence of bytes | 1.8.0 to 3.4.5 |
siii.mdt.svch.mhs | Master Handshake | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.mdt.svch.proc | SVC process | Boolean | 1.8.0 to 3.4.5 |
siii.mdt.svch.rw | Read/Write | Boolean | 1.8.0 to 3.4.5 |
siii.mdt.svch.stat | SvcStat | Unsigned integer, 2 bytes | 1.8.0 to 3.4.5 |
siii.mdt.version | Communication Version | Unsigned integer, 4 bytes | 1.8.0 to 3.4.5 |
siii.mdt.version.initprocvers | Initialization Procedure Version Number | Boolean | 1.8.0 to 3.4.5 |
siii.mdt.version.mdt0_cp0_fast_cp_switch | Fast CP switch | Boolean | 2.0.0 to 3.4.5 |
siii.mdt.version.mdt0_cp0_switch_off_sercos_telegram | Switch off Sercos III telegrams | Boolean | 2.0.0 to 3.4.5 |
siii.mdt.version.mdt0_cp0_transm_comm_parameter | Transmission of Communication parameters | Boolean | 2.0.0 to 3.4.5 |
siii.mdt.version.num_mdt_at_cp1_2 | Number of MDTs and ATS in CP1 and CP2 | Unsigned integer, 4 bytes | 1.8.0 to 3.4.5 |
siii.mdt.version.revision | Revision Number | Unsigned integer, 4 bytes | 1.8.0 to 1.12.13 |
siii.mst.crc32 | CRC32 | Unsigned integer, 4 bytes | 1.8.0 to 3.4.5 |
siii.mst.cyclecnt | Cycle Cnt | Unsigned integer, 1 byte | 1.8.0 to 3.4.5 |
siii.mst.phase | Phase | Unsigned integer, 1 byte | 1.8.0 to 3.4.5 |
siii.service_channels | Service Channels | Label | 2.0.0 to 3.4.5 |
siii.telno | Telegram Number | Unsigned integer, 1 byte | 1.8.0 to 3.4.5 |
siii.type | Telegram Type | Unsigned integer, 1 byte | 1.8.0 to 3.4.5 |
Go Beyond with Riverbed Technology
I have a lot of traffic...
ANSWER: SteelCentral™ AppResponse 11
- • Full stack analysis – from packets to pages
- • Rich performance metrics & pre-defined insights for fast problem identification/resolution
- • Modular, flexible solution for deeply-analyzing network & application performance