Display Filter Reference: OAMPDU
Protocol field name: oampdu
Versions: 2.0.0 to 3.4.5
Back to Display Filter Reference
Field name | Description | Type | Versions |
---|---|---|---|
oampdu.code | OAMPDU code | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.event.efeErrors | Errored Frames | Unsigned integer, 4 bytes | 2.0.0 to 3.4.5 |
oampdu.event.efeThreshold | Errored Frame Threshold | Unsigned integer, 4 bytes | 2.0.0 to 3.4.5 |
oampdu.event.efeTotalErrors | Error Running Total | Unsigned integer, 8 bytes | 2.0.0 to 3.4.5 |
oampdu.event.efeTotalEvents | Event Running Total | Unsigned integer, 4 bytes | 2.0.0 to 3.4.5 |
oampdu.event.efeWindow | Errored Frame Window | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
oampdu.event.efpeThreshold | Errored Frame Threshold | Unsigned integer, 4 bytes | 2.0.0 to 3.4.5 |
oampdu.event.efpeTotalErrors | Error Running Total | Unsigned integer, 8 bytes | 2.0.0 to 3.4.5 |
oampdu.event.efpeTotalEvents | Event Running Total | Unsigned integer, 4 bytes | 2.0.0 to 3.4.5 |
oampdu.event.efpeWindow | Errored Frame Window | Unsigned integer, 4 bytes | 2.0.0 to 3.4.5 |
oampdu.event.efsseThreshold | Errored Frame Threshold | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
oampdu.event.efsseTotalErrors | Error Running Total | Unsigned integer, 4 bytes | 2.0.0 to 3.4.5 |
oampdu.event.efsseTotalEvents | Event Running Total | Unsigned integer, 4 bytes | 2.0.0 to 3.4.5 |
oampdu.event.efsseWindow | Errored Frame Window | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
oampdu.event.espeErrors | Errored Symbols | Unsigned integer, 8 bytes | 2.0.0 to 3.4.5 |
oampdu.event.espeThreshold | Errored Symbol Threshold | Unsigned integer, 8 bytes | 2.0.0 to 3.4.5 |
oampdu.event.espeTotalErrors | Error Running Total | Unsigned integer, 8 bytes | 2.0.0 to 3.4.5 |
oampdu.event.espeTotalEvents | Event Running Total | Unsigned integer, 4 bytes | 2.0.0 to 3.4.5 |
oampdu.event.espeWindow | Errored Symbol Window | Unsigned integer, 8 bytes | 2.0.0 to 3.4.5 |
oampdu.event.length | Event Length | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.event.length.bad | Event length should be at least 2 | Label | 2.0.0 to 3.4.5 |
oampdu.event.mvl.zero | Match Value Field Length is Zero, Match Value Field not Decoded | Label | 3.0.0 to 3.4.5 |
oampdu.event.sequence | Sequence Number | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
oampdu.event.timestamp | Event Timestamp (100ms) | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
oampdu.event.type | Event Type | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.flags | Flags | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
oampdu.flags.criticalEvent | Critical Event | Boolean | 2.0.0 to 3.4.5 |
oampdu.flags.dyingGasp | Dying Gasp | Boolean | 2.0.0 to 3.4.5 |
oampdu.flags.linkFault | Link Fault | Boolean | 2.0.0 to 3.4.5 |
oampdu.flags.localEvaluating | Local Evaluating | Boolean | 2.0.0 to 3.4.5 |
oampdu.flags.localStable | Local Stable | Boolean | 2.0.0 to 3.4.5 |
oampdu.flags.remoteEvaluating | Remote Evaluating | Boolean | 2.0.0 to 3.4.5 |
oampdu.flags.remoteStable | Remote Stable | Boolean | 2.0.0 to 3.4.5 |
oampdu.frame.rate.max | Minimum OAM Rate | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
oampdu.frame.rate.min | Maximum OAM Rate | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
oampdu.info.length | TLV Length | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.info.oamConfig | OAM Configuration | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.info.oamConfig.mode | OAM Mode | Boolean | 2.0.0 to 3.4.5 |
oampdu.info.oampduConfig | Max OAMPDU Size | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
oampdu.info.oui | Organizationally Unique Identifier | Unsigned integer, 3 bytes | 2.0.0 to 3.4.5 |
oampdu.info.revision | TLV Revision | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
oampdu.info.state | OAM DTE States | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.info.state.multiplexer | Multiplexer Action | Boolean | 3.4.0 to 3.4.5 |
oampdu.info.state.muxiplexer | Muxiplexer Action | Boolean | 2.0.0 to 3.2.13 |
oampdu.info.state.parser | Parser Action | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.info.type | Type | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.info.vendor | Vendor Specific Information | Sequence of bytes | 2.0.0 to 3.4.5 |
oampdu.info.version | TLV Version | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.lpbk.commands | Commands | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.lpbk.commands.disable | Disable Remote Loopback | Boolean | 2.0.0 to 3.4.5 |
oampdu.lpbk.commands.enable | Enable Remote Loopback | Boolean | 2.0.0 to 3.4.5 |
oampdu.mll.b | Bidirectional | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
oampdu.mll.do | Downstream-only | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
oampdu.queue_configuration.logical_links.upstream | Upstream Logical Links | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.queue_configuration.ports.downstream | Downstream Ports | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.queue_configuration.queues | Number of queues | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.queue_configuration.size | Queue size (in 4KB units) | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.report.threshold | Report Threshold | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
oampdu.report.threshold.queue | Number of Queue Sets | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.report.threshold.queue.values | Report Values Per Queue Set | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
oampdu.response.eth | OAM Response Value | Ethernet or other MAC address | 2.0.0 to 3.4.5 |
oampdu.response.int | OAM Response Value | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
oampdu.s1.autoneg | Auto-Negotiation Capability | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
oampdu.s1.autoneg.10 | 10 Mbps | Boolean | 2.0.0 to 3.4.5 |
oampdu.s1.autoneg.100 | 100 Mbps | Boolean | 2.0.0 to 3.4.5 |
oampdu.s1.autoneg.1000 | 1000 Mbps | Boolean | 2.0.0 to 3.4.5 |
oampdu.s1.autoneg.10000 | 10Gbps | Boolean | 2.0.0 to 3.4.5 |
oampdu.s1.autoneg.fc | Flow Control | Boolean | 2.0.0 to 3.4.5 |
oampdu.s1.autoneg.fd | Full Duplex | Boolean | 2.0.0 to 3.4.5 |
oampdu.s1.autoneg.hd | Half Duplex | Boolean | 2.0.0 to 3.4.5 |
oampdu.s1.autoneg.mdi | Auto MDI/MDI-X | Boolean | 2.0.0 to 3.4.5 |
oampdu.user.port.object | UNI Number | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
oampdu.user.port.object.clause.fc | Field Code | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.user.port.object.clause.fi | Field Instance | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.user.port.object.clause.lsbm | LSB Mask | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.user.port.object.clause.msbm | MSB Mask | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.user.port.object.clause.mv | Match Value | Sequence of bytes | 2.0.0 to 3.4.5 |
oampdu.user.port.object.clause.mvl | Match Value Length | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.user.port.object.clause.operator | Operator | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.user.port.object.header.precedence | Precedence | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.user.port.object.result.rr | Rule Result | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.user.port.object.result.rr.cd | Field Code not to delete | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.user.port.object.result.rr.ci | Field Code not to insert | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.user.port.object.result.rr.copy | Field Code to set from field used in last clause of rule | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.user.port.object.result.rr.delete | Field Code to remove from frame | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.user.port.object.result.rr.insert | Field Code to insert into frame | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.user.port.object.result.rr.queue | {port type, port instance, link, queue} | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.user.port.object.result.rr.replace | Field Code to replace | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.user.port.object.result.rr.set.fc | Field Code | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.user.port.object.result.rr.set.fi | Field Instance | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.user.port.object.subtype | Subtype | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
oampdu.variable.attribute | Leaf | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
oampdu.variable.binding | Leaf | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
oampdu.variable.branch | Branch | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.variable.descriptor | Variable Descriptor | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.variable.indication | Variable indication | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.variable.object | Leaf | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
oampdu.variable.package | Leaf | Unsigned integer, 2 bytes | 2.0.0 to 3.4.5 |
oampdu.variable.response.code | Response Code | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.variable.value | Variable Value | Sequence of bytes | 2.0.0 to 3.4.5 |
oampdu.variable.width | Variable Width | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
oampdu.vendor.specific.opcode | DPoE Opcode | Unsigned integer, 1 byte | 2.0.0 to 3.4.5 |
Go Beyond with Riverbed Technology
I have a lot of traffic...
ANSWER: SteelCentral™ AppResponse 11
- • Full stack analysis – from packets to pages
- • Rich performance metrics & pre-defined insights for fast problem identification/resolution
- • Modular, flexible solution for deeply-analyzing network & application performance