Display Filter Reference: NVM Express Fabrics RDMA
Protocol field name: nvme-rdma
Versions: 2.4.0 to 3.4.5
Back to Display Filter Reference
Field name | Description | Type | Versions |
---|---|---|---|
nvme-rdma.cm.rej.recfmt | Recfmt | Unsigned integer, 2 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cm.rej.reserved | Reserved | Sequence of bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cm.rej.status | Status | Unsigned integer, 2 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cm.req.hrqsize | HrqSize | Unsigned integer, 2 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cm.req.hsqsize | HsqSize | Unsigned integer, 2 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cm.req.qid | Qid | Unsigned integer, 2 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cm.req.recfmt | Recfmt | Unsigned integer, 2 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cm.req.reserved | Reserved | Sequence of bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cm.rsp.crqsize | CrqSize | Unsigned integer, 2 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cm.rsp.recfmt | Recfmt | Unsigned integer, 2 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cm.rsp.reserved | Reserved | Sequence of bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd | Cmd | Label | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.cid | Command ID | Unsigned integer, 2 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.connect.cattr | Connect Attributes | Unsigned integer, 1 byte | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.connect.data.cntrlid | Controller ID | Unsigned integer, 2 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.connect.data.hostid | Host Identifier | Sequence of bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.connect.data.hostnqn | Host NQN | Character string | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.connect.data.rsvd | Reserved | Sequence of bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.connect.data.rsvd1 | Reserved | Sequence of bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.connect.data.subnqn | Subsystem NQN | Character string | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.connect.kato | Keep Alive Timeout | Unsigned integer, 4 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.connect.qid | Queue ID | Unsigned integer, 2 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.connect.recfmt | Record Format | Unsigned integer, 2 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.connect.rsvd1 | Reserved | Sequence of bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.connect.rsvd2 | Reserved | Sequence of bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.connect.rsvd3 | Reserved | Sequence of bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.connect.sgl1 | SGL1 | Label | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.connect.sqsize | SQ Size | Unsigned integer, 2 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.data | Data | Label | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.fctype | Fabric Cmd Type | Unsigned integer, 1 byte | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.generic.field | Fabric Cmd specific field | Sequence of bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.generic.rsvd1 | Reserved | Sequence of bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.opc | Opcode | Unsigned integer, 1 byte | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.prop_attr.get.rsvd3 | Reserved | Sequence of bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.prop_attr.offset | Offset | Unsigned integer, 4 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.prop_attr.rsvd | Reserved | Sequence of bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.prop_attr.rsvd1 | Reserved | Unsigned integer, 1 byte | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.prop_attr.rsvd2 | Reserved | Sequence of bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.prop_attr.set.rsvd3 | Reserved | Sequence of bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.prop_attr.set.value.4B | Value | Unsigned integer, 4 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.prop_attr.set.value.8B | Value | Unsigned integer, 8 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.prop_attr.set.value.rsvd | Reserved | Unsigned integer, 4 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.prop_attr.size | Property Size | Unsigned integer, 1 byte | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.qid | Cmd Qid | Unsigned integer, 2 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cmd.rsvd | Reserved | Unsigned integer, 1 byte | 2.4.0 to 3.4.5 |
nvme-rdma.cmd_latency | Cmd Latency | Floating point (double-precision) | 2.4.0 to 3.4.5 |
nvme-rdma.cmd_pkt | Fabric Cmd in | Frame number | 2.4.0 to 3.4.5 |
nvme-rdma.cqe | Cqe | Label | 2.4.0 to 3.4.5 |
nvme-rdma.cqe.cid | Command ID | Unsigned integer, 2 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cqe.connect.authreq | Authentication Required | Unsigned integer, 2 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cqe.connect.cntrlid | Controller ID | Unsigned integer, 2 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cqe.connect.rsvd | Reserved | Sequence of bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cqe.prop_set.rsvd | Reserved | Sequence of bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cqe.rsvd | Reserved | Unsigned integer, 2 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cqe.sqhd | SQ Head Pointer | Unsigned integer, 2 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cqe.status | Status | Unsigned integer, 2 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cqe.status.rsvd | Reserved | Unsigned integer, 2 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cqe.sts | Cmd specific Status | Unsigned integer, 8 bytes | 2.4.0 to 3.4.5 |
nvme-rdma.cqe_pkt | Fabric Cqe in | Frame number | 2.4.0 to 3.4.5 |
nvme-rdma.unknown_data | Dissection unsupported | Sequence of bytes | 2.4.0 to 3.4.5 |
Go Beyond with Riverbed Technology
I have a lot of traffic...
ANSWER: SteelCentral™ AppResponse 11
- • Full stack analysis – from packets to pages
- • Rich performance metrics & pre-defined insights for fast problem identification/resolution
- • Modular, flexible solution for deeply-analyzing network & application performance