Display Filter Reference: FTDI FT USB
Protocol field name: ftdift
Versions: 3.2.0 to 3.2.13
Back to Display Filter Reference
Field name | Description | Type | Versions |
---|---|---|---|
ftdift.bRequest | Request | Unsigned integer, 1 byte | 3.2.0 to 3.2.13 |
ftdift.hIndex | hIndex | Unsigned integer, 1 byte | 3.2.0 to 3.2.13 |
ftdift.hIndex.b0 | RTS/CTS Flow Control | Boolean | 3.2.0 to 3.2.13 |
ftdift.hIndex.b1 | DTR/DSR Flow Control | Boolean | 3.2.0 to 3.2.13 |
ftdift.hIndex.b2 | XON/XOFF Flow Control | Boolean | 3.2.0 to 3.2.13 |
ftdift.hValue | hValue | Unsigned integer, 1 byte | 3.2.0 to 3.2.13 |
ftdift.hValue.b0 | en DTR for writing | Boolean | 3.2.0 to 3.2.13 |
ftdift.hValue.b1 | en RTS for writing | Boolean | 3.2.0 to 3.2.13 |
ftdift.hValue.b4 | Stop Bits | Unsigned integer, 1 byte | 3.2.0 to 3.2.13 |
ftdift.hValue.b6 | Break Bit | Unsigned integer, 1 byte | 3.2.0 to 3.2.13 |
ftdift.hValue.parity | Parity | Unsigned integer, 1 byte | 3.2.0 to 3.2.13 |
ftdift.if_a_rx_payload | A RX payload | Sequence of bytes | 3.2.0 to 3.2.13 |
ftdift.if_a_tx_payload | A TX payload | Sequence of bytes | 3.2.0 to 3.2.13 |
ftdift.if_b_rx_payload | B RX payload | Sequence of bytes | 3.2.0 to 3.2.13 |
ftdift.if_b_tx_payload | B TX payload | Sequence of bytes | 3.2.0 to 3.2.13 |
ftdift.if_c_rx_payload | C RX payload | Sequence of bytes | 3.2.0 to 3.2.13 |
ftdift.if_c_tx_payload | C TX payload | Sequence of bytes | 3.2.0 to 3.2.13 |
ftdift.if_d_rx_payload | D RX payload | Sequence of bytes | 3.2.0 to 3.2.13 |
ftdift.if_d_tx_payload | D TX payload | Sequence of bytes | 3.2.0 to 3.2.13 |
ftdift.latency_time | Latency Time | Unsigned integer, 1 byte | 3.2.0 to 3.2.13 |
ftdift.lIndex | lIndex | Unsigned integer, 1 byte | 3.2.0 to 3.2.13 |
ftdift.lIndex.b0 | Baud High | Unsigned integer, 1 byte | 3.2.0 to 3.2.13 |
ftdift.line_status | Line Status | Unsigned integer, 1 byte | 3.2.0 to 3.2.13 |
ftdift.line_status.b1 | Receive Overflow Error | Boolean | 3.2.0 to 3.2.13 |
ftdift.line_status.b2 | Parity Error | Boolean | 3.2.0 to 3.2.13 |
ftdift.line_status.b3 | Framing Error | Boolean | 3.2.0 to 3.2.13 |
ftdift.line_status.b4 | Break Received | Boolean | 3.2.0 to 3.2.13 |
ftdift.line_status.b5 | Transmitter Holding Register Empty | Boolean | 3.2.0 to 3.2.13 |
ftdift.line_status.b6 | Transmitter Empty | Boolean | 3.2.0 to 3.2.13 |
ftdift.lValue | lValue | Unsigned integer, 1 byte | 3.2.0 to 3.2.13 |
ftdift.lValue.b0 | DTR Active | Boolean | 3.2.0 to 3.2.13 |
ftdift.lValue.b1 | RTS Active | Boolean | 3.2.0 to 3.2.13 |
ftdift.modem_status | Modem Status | Unsigned integer, 1 byte | 3.2.0 to 3.2.13 |
ftdift.modem_status.b0 | Full Speed 64 byte MAX packet | Boolean | 3.2.0 to 3.2.13 |
ftdift.modem_status.b1 | High Speed 512 byte MAX packet | Boolean | 3.2.0 to 3.2.13 |
ftdift.modem_status.b4 | CTS | Boolean | 3.2.0 to 3.2.13 |
ftdift.modem_status.b5 | DSR | Boolean | 3.2.0 to 3.2.13 |
ftdift.modem_status.b6 | RI | Boolean | 3.2.0 to 3.2.13 |
ftdift.modem_status.b7 | DCD | Boolean | 3.2.0 to 3.2.13 |
ftdift.undecoded | Not dissected yet (report to wireshark.org) | Label | 3.2.0 to 3.2.13 |
ftdift.wLength | wLength | Unsigned integer, 2 bytes | 3.2.0 to 3.2.13 |