Display Filter Reference: evolved Common Public Radio Interface
Protocol field name: ecpri
Versions: 3.2.0 to 3.4.5
Back to Display Filter Reference
Field name | Description | Type | Versions |
---|---|---|---|
ecpri.actiontype | Action Type | Unsigned integer, 1 byte | 3.2.0 to 3.4.5 |
ecpri.addinfo | Additional Information | Unsigned integer, 4 bytes | 3.2.0 to 3.4.5 |
ecpri.address | Address | Sequence of bytes | 3.2.0 to 3.4.5 |
ecpri.cbit | C-Bit | Unsigned integer, 1 byte | 3.2.0 to 3.4.5 |
ecpri.comp.val.invalid | Invalid Compensation Value | Label | 3.2.0 to 3.4.5 |
ecpri.compval | Compensation Value | Unsigned integer, 8 bytes | 3.2.0 to 3.4.5 |
ecpri.concat.bit.invalid | Invalid Concatenation Bit | Label | 3.2.0 to 3.4.5 |
ecpri.data | User Data | Sequence of bytes | 3.2.0 to 3.4.5 |
ecpri.data.length.invalid | Invalid Data Length | Label | 3.2.0 to 3.4.5 |
ecpri.element | Element | Sequence of bytes | 3.2.0 to 3.4.5 |
ecpri.elementid | Element ID | Unsigned integer, 2 bytes | 3.2.0 to 3.4.5 |
ecpri.eventid | Event ID | Unsigned integer, 1 byte | 3.2.0 to 3.4.5 |
ecpri.eventtype | Event Type | Unsigned integer, 1 byte | 3.2.0 to 3.4.5 |
ecpri.fault.notif.invalid | Invalid Fault/Notification | Label | 3.2.0 to 3.4.5 |
ecpri.faultnotif | Fault/Notification | Unsigned integer, 2 bytes | 3.2.0 to 3.4.5 |
ecpri.frame.length.invalid | Invalid eCPRI Frame Length | Label | 3.2.0 to 3.4.5 |
ecpri.header | eCPRI Common Header | Unsigned integer, 4 bytes | 3.2.0 to 3.4.5 |
ecpri.length | Data Length | Unsigned integer, 2 bytes | 3.2.0 to 3.4.5 |
ecpri.measurementid | Measurement ID | Unsigned integer, 1 byte | 3.2.0 to 3.4.5 |
ecpri.nanosec | Nanoseconds | Unsigned integer, 4 bytes | 3.2.0 to 3.4.5 |
ecpri.not_dissected_yet | Not dissected yet | Label | 3.2.0 to 3.4.5 |
ecpri.num.faults.invalid | Invalid Number of Faults | Label | 3.2.0 to 3.4.5 |
ecpri.numberfaultnotif | Number of Faults/Notifications | Unsigned integer, 1 byte | 3.2.0 to 3.4.5 |
ecpri.payload | eCPRI Payload | Sequence of bytes | 3.2.0 to 3.4.5 |
ecpri.payload.size.invalid | Invalid Payload Size | Label | 3.2.0 to 3.4.5 |
ecpri.pcid | PC_ID | Unsigned integer, 2 bytes | 3.2.0 to 3.4.5 |
ecpri.raisecease | Raise/Cease | Unsigned integer, 1 byte | 3.2.0 to 3.4.5 |
ecpri.reqresp | Request/Response | Unsigned integer, 1 byte | 3.2.0 to 3.4.5 |
ecpri.reserved | Reserved | Unsigned integer, 1 byte | 3.2.0 to 3.4.5 |
ecpri.resetcode | Reset Code Op | Unsigned integer, 1 byte | 3.2.0 to 3.4.5 |
ecpri.resetid | Reset ID | Unsigned integer, 2 bytes | 3.2.0 to 3.4.5 |
ecpri.revision | Protocol Revision | Unsigned integer, 1 byte | 3.2.0 to 3.4.5 |
ecpri.rmaid | Remote Memory Access ID | Unsigned integer, 1 byte | 3.2.0 to 3.4.5 |
ecpri.rtcid | RTC_ID | Unsigned integer, 2 bytes | 3.2.0 to 3.4.5 |
ecpri.rw | Read/Write | Unsigned integer, 1 byte | 3.2.0 to 3.4.5 |
ecpri.sec | Seconds | Unsigned integer, 6 bytes | 3.2.0 to 3.4.5 |
ecpri.seqid | SEQ_ID | Unsigned integer, 2 bytes | 3.2.0 to 3.4.5 |
ecpri.seqnum | Sequence Number | Unsigned integer, 1 byte | 3.2.0 to 3.4.5 |
ecpri.size | Payload Size | Unsigned integer, 2 bytes | 3.2.0 to 3.4.5 |
ecpri.time.stamp.invalid | Invalid Time Stamp | Label | 3.2.0 to 3.4.5 |
ecpri.timestamp | Time Stamp | Sequence of bytes | 3.2.0 to 3.4.5 |
ecpri.type | Message Type | Unsigned integer, 1 byte | 3.2.0 to 3.4.5 |
Go Beyond with Riverbed Technology