Display Filter Reference: ZigBee ZCL Pump Configuration and Control

Protocol field name: zbee_zcl_hvac.pump_config_ctrl

Versions: 2.2.0 to 3.4.5

Back to Display Filter Reference

Field name Description Type Versions
zbee_zcl_hvac.pump_config_control.attr.alarm Alarm Mask Unsigned integer, 2 bytes 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.alarm.dry_running Dry running Boolean 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.alarm.elec_fatal_fail Electronic fatal failure Boolean 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.alarm.elec_non_fatal_fail Electronic non-fatal failure Boolean 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.alarm.elec_temp_too_high Electronic temperature too high Boolean 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.alarm.gen_fault General fault Boolean 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.alarm.mtr_fatal_fail Pump motor has fatal failure Boolean 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.alarm.mtr_temp_too_high Motor temperature too high Boolean 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.alarm.press_too_high System pressure too high Boolean 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.alarm.press_too_low System pressure too low Boolean 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.alarm.pump_block Pump blocked Boolean 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.alarm.pwr_missing_phase Power missing phase Boolean 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.alarm.sensor_fail Sensor failure Boolean 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.alarm.volt_too_high Supply voltage too high Boolean 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.alarm.volt_too_low Supply voltage too low Boolean 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.ctrl_mode Effective Control Mode Unsigned integer, 1 byte 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.effective_opr_mode Effective Operation Mode Unsigned integer, 1 byte 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.opr_mode Operation Mode Unsigned integer, 1 byte 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.status Pump Status Unsigned integer, 2 bytes 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.status.device_fault Device Fault Boolean 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.status.local_override Local Override Boolean 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.status.rem_flow Remote Flow Boolean 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.status.rem_pressure Remote Pressure Boolean 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.status.rem_temp Remote Temperature Boolean 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.status.running Running Boolean 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.status.speed_high Speed High Boolean 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.status.speed_low Speed Low Boolean 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr.status.supply_fault Supply Fault Boolean 2.2.0 to 3.4.5
zbee_zcl_hvac.pump_config_control.attr_id Attribute Unsigned integer, 2 bytes 2.2.0 to 3.4.5
Go Beyond with Riverbed Technology

Riverbed is Wireshark's primary sponsor and provides our funding. They also make great products that fully integrate with Wireshark.

I have a lot of traffic...

ANSWER: SteelCentral™ AppResponse 11
  • • Full stack analysis – from packets to pages
  • • Rich performance metrics & pre-defined insights for fast problem identification/resolution
  • • Modular, flexible solution for deeply-analyzing network & application performance
Learn More